Running a demo
The simulator plays every room computer of a small ward: 5 residents in rooms 11 to 14, room 13 with two beds, 29 sensors. The backend cannot tell it from real hardware.
cd edge/simulatoruv run simulator_gui.py # buttons: a card per resident, a panel per room, the devices tableuv run simulator.py # or the terminal; Tab completes commandsOnly one simulator can run against a broker at a time; a second one is refused.
Scenarios
Section titled “Scenarios”| Scenario | Window | Terminal | What you should see |
|---|---|---|---|
| Stops breathing | Apnea on a resident card | apnea 1 |
No breathing after ~10 s, escalated after 30 s more |
| Low oxygen | Low SpO2 | lowspo2 4 |
Low oxygen |
| One odd signal | Noisy | noisy 2 |
Nothing: one sign is not enough |
| A fall | Fall | fall 1 |
Possible fall for that resident only |
| Call bell | Bell | bell 5 |
A critical bell alert |
| Crying in a room | Cry on a room panel | cry 3 |
One soft Check every bed for the room |
| A sensor dies | Crash in the devices table | crash radar-002 |
Sensor offline, never No breathing |
| A new sensor | Plug in | plug radar 14 |
A pending radar in the control room |
In the terminal, the number is the resident (1 to 5), not the room. After a scenario, Back to normal
(normal 1) and wait about 20 seconds before running it again.
Let the ward run three minutes before the first scenario: the personal baselines need history.
The laptop microphone
Section titled “The laptop microphone”cd edge/micsensor && uv run mic_sensor.py --room room12Stay quiet for the first three seconds while it learns the room. Approve mic-laptop in the control room; a loud
clap or call raises Check every bed for room 12. It measures loudness, not words.
Before a live demo
Section titled “Before a live demo”- Stop every simulator and the server; reset the broker:
docker compose rm -sfv mosquitto && docker compose up -d mosquitto. - Start the server, then exactly one simulator; approve all sensors, then room 13’s by hand (two beds).
- Wait three minutes; check the station shows All clear and Live.
- Keep the laptop lid open and the charger in: a sleeping laptop makes every sensor look offline.