Skip to content

Privacy, safety and limits

  • Local only. The server, the database and every screen run inside the building, on its own network.
  • No recordings. Sound is analysed in the room; only a score (“distress 0.8”) leaves it. Nothing is recorded.
  • Pseudonyms. The prototype uses no real patient data, ever.
  • Never fails silently. Every sensor reports that it is alive every 5 seconds; a sensor that goes quiet, or whose connection drops, raises Sensor offline within seconds. A screen that loses the server says Not live.
  • Everything is on the record. Approvals, alerts, acknowledgements, pages and rule changes are journaled, with when they happened. The server rebuilds its state from that journal after a restart.
  • A bell is never ignored. A pressed call bell always raises a critical alert, even on an empty bed.
  • It is a supplementary alert: it adds to rounds and standard monitoring, never replaces them.
  • Thresholds are demonstration values until the clinical team signs each one off.
  • Security is not done: the control room PIN is a demonstration gate; accounts, roles, encrypted links and per-device credentials come before any real use.
  • Sound recognition today is loudness, not a trained classifier: a clap scores like a call for help. Recognising choking or crying needs real recordings, collected with consent.
  • Approvals: room microphones need privacy approval, and the regulatory status must be confirmed.